In normal circumstances, please configure the baud rate at start-up, not in the parameter settings. The baud rate in the parameter setting is configured in advanced mode, which is generally used fo...
Yes. Up to 10 USB_CAN adapters can be connected to a computer at the same time and 4 adapters can be opened by the USB-CAN Tool debugging tool. Please refer to the "Appendix 5: Multi-Card with ...
Solution: As shown in the figure below, the error is: the application cannot start normally 0xc0150002. download and install VC2008 runtime library vcredist_x86 and it will be fine.
Solution: The CAN transceiver used in the USB_CAN Adapter/CANalyst-II Analyzer is the TJA1040T high-speed CAN transceiver. This series of transceivers is the most versatile and can be used in any h...
Solution: To ensure that the sent data is not lost, the USB-CAN device has an automatic retransmission function. If the USB-CAN device is not connected to the CAN bus, the baud rate does not match ...
After successfully testing two channels for sending and receiving data, it was discovered that the target bus or device could not be accessed to read the data.Solution: The mutual transceiver te...
Solution: Due to some security settings, the configuration file cannot be generated. Right click USB_CAN TOOL shortcut, select "Run as administrator", so that the USB_CAN TOOL installation dire...
Solution: Baud rate deviation can receive data, but may be unstable, the international standard is 1% range can be that is, 250K Set 250 + 1% * 250K can be. However, other baud rates around 250...
Solution: The baud rate detection principle involves continuously changing the baud rate of the USBCAN device when data is sent on the bus. The receive error flag and receive interrupt flag are ...
In the process of using, it has successfully received data, but after modifying the configuration, it can no longer receive data. According to the instruction manual to do the test of sending and r...
During using, data has been successfully received, but after modifying the configuration, data can no longer be received. How to restore the factory settings of the debugging software USB_CAN TOOL....
Prescription: The possible reason for this failure is that the USB_CAN adapter driver has not been installed properly. To resolve this issue, install the USBCAN device driver according to the m...
There is only one type of USB driver, WinUSB, but the name may vary depending on the system and model. The names commonly used are USBCAN Device, CANalyst-II Device, and WinUSB Device. It is no...
Two 120-ohm termination resistors must be guaranteed on the bus or the CAN bus will not function properly.120Ω termination matching resistors are used to absorb endpoint reflections and provide a s...
For our USBCAN-2A/2C, CANalyst-II Analyzer and other CAN adapter products, the driver can be installed normally on most XP systems and will appear in the device manager.WinUSB Device. some xp syste...